Device circuit breakers - Phoenix Contact
Phoenix Contact offers a comprehensive range of device circuit breakers designed to ensure the safety and reliability of electrical installations. These advanced circuit breakers are engineered to protect electrical circuits from damage caused by excess current, typically resulting from an overload or short circuit. Phoenix Contact's device circuit breakers are renowned for their precision, durability, and versatility, making them suitable for a variety of industrial applications.
The product line includes thermal-magnetic circuit breakers, electronic circuit breakers, and a range of specialized circuit breakers tailored to meet specific requirements. Phoenix Contact's electronic circuit breakers, for instance, are programmable and can be easily integrated into automation systems, providing smart solutions that enhance system monitoring and control. This integration capability allows for precise settings and remote troubleshooting, significantly reducing downtime and maintenance costs.
Moreover, Phoenix Contact emphasizes user safety and compliance with international standards, ensuring that all their circuit breakers meet rigorous quality and safety criteria. With easy installation features, compact designs, and robust construction, Phoenix Contact's device circuit breakers are a top choice for professionals seeking reliable electrical protection solutions in demanding environments.
-
Phoenix Contact
- Charging technology for e-mobility
- Terminal blocks
- Industrial communication
- Industrial lighting and signal lights
- Electronics housings
- Worker assistance systems
- Automation software
- Ferrules and crimp connectors
- Surge protection
- Safety relay modules and sensors
- DC/DC converters and DC/AC inverters
- PCB terminal blocks and PCB connectors
- Automatic tools
- Printers
- Uninterruptible power supplies (UPS)
- Hand tools
- Relays and optocouplers
- System cabling for controllers
- Power supplies
- Distributors, adapters, and conductor connectors
- Process indicators and field devices
- Redundancy modules
- Marking material
- Motor, machine, and system monitoring
- PLCs (controllers) and I/Os
- HMIs and IPCs
- I/O signal marshalling
- Cables and lines
- Energy monitoring
- Control cabinet accessories
- Connectors
- Device circuit breakers
- Motor starters and electronic switching devices
- Signal conditioners and measuring transducers
- Plug-in test system
- Edge computing
- Junction boxes and empty enclosures
- Distribution blocks
- Miscellaneous
- Board-to-board connectors
- Power distributors
- Ferrules
- Distribution blocks and device terminal blocks
- EMC filter
- Navigation
Filter products
304 Products Ready to Source
1-channel thermal device circuit breaker for protecting loads at 250 V AC / 72 V DC in the event of an overload. For installation on fuse terminal blocks and interfaces for flat plug-in fuse of type C according to standard ISO 8820-3. With fixed nominal current: 0.1 A Thermal device circuit breaker
1-channel thermal device circuit breaker for protecting loads at 250 V AC / 72 V DC in the event of an overload. For installation on fuse terminal blocks and interfaces for flat plug-in fuse of type C according to standard ISO 8820-3. With fixed nominal current: 0.25 A Thermal device circuit breaker
1-channel thermal device circuit breaker for protecting loads at 250 V AC / 72 V DC in the event of an overload. For installation on fuse terminal blocks and interfaces for flat plug-in fuse of type C according to standard ISO 8820-3. With fixed nominal current: 0.5 A Thermal device circuit breaker
1-channel thermal device circuit breaker for protecting loads at 250 V AC / 72 V DC in the event of an overload. For installation on fuse terminal blocks and interfaces for flat plug-in fuse of type C according to standard ISO 8820-3. With fixed nominal current: 1 A Thermal device circuit breaker
1-channel thermal device circuit breaker for protecting loads at 250 V AC / 72 V DC in the event of an overload. For installation on fuse terminal blocks and interfaces for flat plug-in fuse of type C according to standard ISO 8820-3. With fixed nominal current: 2 A Thermal device circuit breaker
1-channel thermal device circuit breaker for protecting loads at 250 V AC / 72 V DC in the event of an overload. For installation on fuse terminal blocks and interfaces for flat plug-in fuse of type C according to standard ISO 8820-3. With fixed nominal current: 3 A Thermal device circuit breaker
1-channel thermal device circuit breaker for protecting loads at 250 V AC / 72 V DC in the event of an overload. For installation on fuse terminal blocks and interfaces for flat plug-in fuse of type C according to standard ISO 8820-3. With fixed nominal current: 4 A Thermal device circuit breaker
1-channel thermal device circuit breaker for protecting loads at 250 V AC / 72 V DC in the event of an overload. For installation on fuse terminal blocks and interfaces for flat plug-in fuse of type C according to standard ISO 8820-3. With fixed nominal current: 6 A Thermal device circuit breaker
1-channel thermal device circuit breaker for protecting loads at 250 V AC / 72 V DC in the event of an overload. For installation on fuse terminal blocks and interfaces for flat plug-in fuse of type C according to standard ISO 8820-3. With fixed nominal current: 8 A Thermal device circuit breaker
1-channel thermal device circuit breaker for protecting loads at 250 V AC / 72 V DC in the event of an overload. For installation on fuse terminal blocks and interfaces for flat plug-in fuse of type C according to standard ISO 8820-3. With fixed nominal current: 10 A Thermal device circuit breaker
Single plug-in bridge, length: 21 mm, color: gray Single plug-in bridge
Continuous plug-in bridge, mounting type: Plug-in mounting Continuous plug-in bridge
Electronic circuit breaker, signal contact: 1 N/O contact, nominal current: 0.5 A Electronic circuit breaker
Electronic circuit breaker, signal contact: 1 N/O contact, nominal current: 1 A Electronic circuit breaker
Electronic circuit breaker, signal contact: 1 N/O contact, nominal current: 2 A Electronic circuit breaker
Electronic circuit breaker, signal contact: 1 N/O contact, nominal current: 3 A Electronic circuit breaker
Electronic circuit breaker, signal contact: 1 N/O contact, nominal current: 4 A Electronic circuit breaker
Electronic circuit breaker, signal contact: 1 N/O contact, nominal current: 6 A Electronic circuit breaker
Electronic circuit breaker, signal contact: 1 N/O contact, nominal current: 8 A Electronic circuit breaker
Electronic circuit breaker, signal contact: 1 N/O contact, nominal current: 10 A Electronic circuit breaker
Electronic circuit breaker, signal contact: 1 N/O contact, nominal current: 12 A Electronic circuit breaker
Electronic circuit breaker, signal contact: 1 N/C contact, nominal current: 1 A Electronic circuit breaker
Electronic circuit breaker, signal contact: 1 N/C contact, nominal current: 2 A Electronic circuit breaker
Electronic circuit breaker, signal contact: 1 N/C contact, nominal current: 3 A Electronic circuit breaker
Electronic circuit breaker, signal contact: 1 N/C contact, nominal current: 4 A Electronic circuit breaker
Electronic circuit breaker, signal contact: 1 N/C contact, nominal current: 6 A Electronic circuit breaker
Electronic circuit breaker, signal contact: 1 N/C contact, nominal current: 8 A Electronic circuit breaker
Electronic circuit breaker, signal contact: 1 N/C contact, nominal current: 10 A Electronic circuit breaker
Electronic circuit breaker, signal contact: 1 N/C contact, nominal current: 12 A Electronic circuit breaker
Electronic circuit breaker, 1 reset input, nominal current: 0.5 A Electronic circuit breaker
Electronic circuit breaker, 1 reset input, nominal current: 1 A Electronic circuit breaker
Electronic circuit breaker, 1 reset input, nominal current: 2 A Electronic circuit breaker
Electronic circuit breaker, 1 reset input, nominal current: 3 A Electronic circuit breaker
Electronic circuit breaker, 1 reset input, nominal current: 4 A Electronic circuit breaker
Electronic circuit breaker, 1 reset input, nominal current: 6 A Electronic circuit breaker