I/O signal marshalling - Phoenix Contact
Phoenix Contact offers advanced solutions for I/O signal marshalling, streamlining the complex process of organizing and managing data transfers between various industrial components. Their systems are designed to enhance efficiency and reliability in the automation sector, accommodating a wide range of signal types and offering robust connectivity options.
The unique technology provided by Phoenix Contact allows for flexible and scalable configurations, making it suitable for both small-scale projects and extensive industrial operations. They emphasize ease of use, with clear labeling and modular designs that simplify installation and maintenance. Additionally, their products support a range of communication protocols, ensuring compatibility with existing systems and future expandability.
Moreover, Phoenix Contact is known for its commitment to quality and durability, providing solutions that withstand harsh industrial environments. This durability, coupled with advanced error-detection features, ensures that the I/O signal marshalling systems are not only functional but also secure from operational risks, thereby preserving the integrity of the control processes they manage.
-
Phoenix Contact
- Charging technology for e-mobility
- Terminal blocks
- Industrial communication
- Industrial lighting and signal lights
- Electronics housings
- Worker assistance systems
- Automation software
- Ferrules and crimp connectors
- Surge protection
- Safety relay modules and sensors
- DC/DC converters and DC/AC inverters
- PCB terminal blocks and PCB connectors
- Automatic tools
- Printers
- Uninterruptible power supplies (UPS)
- Hand tools
- Relays and optocouplers
- System cabling for controllers
- Power supplies
- Distributors, adapters, and conductor connectors
- Process indicators and field devices
- Redundancy modules
- Marking material
- Motor, machine, and system monitoring
- PLCs (controllers) and I/Os
- HMIs and IPCs
- I/O signal marshalling
- Cables and lines
- Energy monitoring
- Control cabinet accessories
- Connectors
- Device circuit breakers
- Motor starters and electronic switching devices
- Signal conditioners and measuring transducers
- Plug-in test system
- Edge computing
- Junction boxes and empty enclosures
- Distribution blocks
- Miscellaneous
- Board-to-board connectors
- Power distributors
- Ferrules
- Distribution blocks and device terminal blocks
- EMC filter
- Navigation
Filter products
59 Products Ready to Source
Fuse module for VIP I/O marshalling base elements with replaceable 2 A fuse in the field device supply path. Integrated test points and a disconnect knife allow uninterrupted signal measurement. HART transparent. Input/output module
Cable monitoring module for VIP I/O marshalling base elements. Enables cable fault monitoring when using standard switching contacts in safety applications. Both wire breaks and short circuits can be detected. Monitoring block
Fuse set, number: 10 Pcs., nominal current: 1 A, tripping characteristic: slow-blow (T) Fuse set
Fuse set, number: 10 Pcs., nominal current: 3.15 A, tripping characteristic: slow-blow (T) Fuse set
16-channel VIP I/O marshalling base element with 37-pos. D-SUB connector for universal use. Plug-in field and supply terminals available as accessories. With Push-in connection technology. For either Ex i or non-Ex. Base module
Plug for cold junction compensation for thermocouples, in combination with MACX MCR(-EX)-TC... temperature transducers Plug
Digital-to-analog converter for VIP I/O-Marshalling base elements. For connection of four digital inputs and conversion to a single analog 4...20 mA signal. Saves three I/O channels. Converter
Non-incendive, Ex ic impeding devices for VIP I/O marshalling base elements. For limiting current (60 mA or 80 mA) and voltage (26.4 V DC) on digital outputs. For example, to control solenoid valves in the Ex area (zone 2, CID2). Feed-through plug
Fuse module for VIP I/O marshalling base elements with replaceable 0.25 A fuse in the field device supply path. Integrated test points and a disconnect knife allow uninterrupted signal measurement. HART transparent. Input/output module
Fuse set, number: 10 Pcs., nominal current: 0.315 A, tripping characteristic: slow-blow (T) Fuse set
Fuse set, number: 10 Pcs., nominal current: 2.5 A, tripping characteristic: slow-blow (T) Fuse set
Connector set for standard applications for use with BASE-MSTB/D37M/16CH/EX VIP I/O marshalling base element with Push-in connection. Connector set
Cable set for signal transmission on the Termination Carrier for modules from the MACX Analog Ex series. Connection of terminal points 3.1 and 3.2 (signal transmission) to the signal PCB. Cable set
Cable set for signal transmission and power supply on the Termination Carrier for modules from the MACX Analog Ex series. Connection of terminal points 3.1 and 3.2 (signal transmission) as well as 1.1 and 1.2 (power supply) to the signal PCB via a 4-pos. PTSM connector. Cable set
Cable set for signal transmission and power supply on the Termination Carrier for signal conditioners from the MACX Analog Ex series. Connection of terminal points 3.2 and 2.2 (signal transmission for active input cards) as well as 1.1 and 1.2 (power supply) to the signal PCB. Cable set
Universal termination carrier for redundantly connecting 16 PSR-FSP modules to digital output cards, via two D-SUB connectors, 37-pos. (1:1 connection). Solution for Emergency Shut Down (ESD) applications. Module carrier
Universal termination carrier for connecting 16 MACX Analog Ex i signal conditioners to digital or analog I/O cards, via D-SUB connector, 37-pos. (1:1 connection), with HART multiplexer connection Module carrier
Universal termination carrier for connecting 16 MINI Analog signal conditioners to digital or analog I/O cards, via D-SUB connector, 37-pos. (1:1 connection) Module carrier
Universal termination carrier for connecting 16 MINI Analog signal conditioners to digital or analog I/O cards, via D-SUB connector, 37-pos. (1:1 connection), with HART multiplexer connection Module carrier
Cable set for signal transmission and power supply on the Termination Carrier for modules from the MINI Analog and PSR mini series. Connection of terminal points 5 and 6 (signal transmission) as well as 7 and 8 (power supply) to the signal PCB. Cable set
Cable set for MINI MCR-SL-PTB power module (Item No. 2864134) and MINI MCR-SL-TB feed-through module (Item No. 2811420), for use on the termination carrier for modules from the MINI Analog series. Cable set
Jumper plug, for looping through the confirmation contacts of unused module slots. Use on the termination carrier for safety relay modules from the PSR-FSP series. Plug
Cable set for signal transmission on the Termination Carrier for coupling relays from the PSR-FSP series. Connection of terminal points A1 and A2 (signal transmission) to the signal PCB. Suitable for PSR-SCP-24DC/FSP/1X1/1X2 (Item No. 2981978). Cable set
Cable set for signal transmission on the Termination Carrier for coupling relays from the PSR-FSP series. Connection of terminal points A1 and A2 (signal transmission) as well as 31 and 32 (confirmation). Suitable for PSR-SCP-24DC/FSP/2X1/1X2 (Item No. 2986960) and PSR-SCP-24DC/FSP2/2X1/1X2 (Item No. 2986575). Cable set
Cable set for signal transmission and power supply on the Termination Carrier for coupling relays from the PSR-ETP series. Connection of terminal points A1 and A2 (signal transmission) as well as V+ (power supply) to the signal PCB. Suitable for PSR-SCP-24DC/ETP/1X1 (Item No. 2986711). Cable set
Termination carrier for redundantly connecting 16 PSR-FSP modules to digital output cards of the Yokogawa ProSafe-RS controller, via two KS50 connectors, 50-pos. Solution for Emergency Shut Down (ESD) applications. Suitable for Yokogawa SDV541 card. Module carrier
Cable set for signal transmission and power supply on the Termination Carrier for signal conditioners from the MACX Analog Ex series. Connection of terminal points 3.2 and 2.2 (signal transmission for active input cards) to the signal PCB. Cable set
Power and fault signaling module with screw connection, only for use on the Termination Carrier, excluding corresponding DIN rail bus connector Power and error message module
Cable set for signal transmission on the Termination Carrier for two-channel modules or modules with double output from the MACX Analog Ex series. Connection of terminal points 3.1 and 3.2 as well as 2.1 and 2.2 (signal transmission) to the signal PCB. Cable set
Termination Carrier for redundantly connecting 16 two-channel MACX Analog Ex i NAMUR signal conditioners to digital input cards of the Yokogawa Centum VP controller, via two KS50 connectors, 50-pos. Suitable for Yokogawa ADV151 and ADV161 cards. Module carrier
Termination carrier for connecting 16 PSR-FSP modules to digital output cards of the Invensys Triconex controller via ELCO connector 8016, 56-pos. Solution for Emergency Shut Down (ESD) applications. Suitable for Invensys Triconex 3625 card. Module carrier
Universal Termination Carrier for connecting 16 two-channel MACX Analog Ex i signal conditioners to digital or analog I/O cards, via two D-SUB connectors, 37-pos. (1:1 connection) Module carrier
Termination Carrier for connecting 16 MACX Analog Ex i signal conditioners to the Honeywell Remote Universal Safe IO System via D-SUB connector, 37-pos. Suitable for the Honeywell card FC-RUSIO-3224. Module carrier
Termination Carrier for redundantly connecting 32 MACX Analog Ex i solenoid drivers to digital output cards of the Yokogawa Centum VP controller, via two KS50 connectors, 50-pos. Suitable for Yokogawa ADV551 and ADV561 cards. Module carrier
Termination carrier for redundantly connecting 16 MACX Analog Ex i signal conditioners to analog output cards of the Yokogawa Centum VP controller, via two KS40 connectors, 40-pos. Suitable for Yokogawa card AAI543. Module carrier
Termination Carrier for redundantly connecting 16 MACX Analog Ex i NAMUR signal conditioners to digital input cards of the Yokogawa ProSafe-RS controller, via two KS50 connectors, 50-pos. Suitable for Yokogawa SDV144 card. Module carrier