Signal marshalling for universal I/O systems - Phoenix Contact
Signal marshalling is a critical component in automation technologies, maintaining robust and efficient communication paths in universal I/O systems. Phoenix Contact, a leader in electrical connection technology, offers advanced solutions for signal marshalling that are designed to cater to the diverse needs of modern industrial setups. These systems are engineered to streamline the configuration and operation of I/O signals, ensuring high reliability and ease of use.
Phoenix Contact's signal marshalling systems utilize innovative marshalling technology that simplifies the routing of signals from field devices to control systems. By effectively managing the complexity associated with wiring, these solutions reduce installation time and minimize potential errors. Their modular design allows for flexibility and scalability, enabling users to expand or modify their systems as necessary without major disruptions or extensive downtime.
Furthermore, the universal I/O systems from Phoenix Contact support a wide range of signal types and are compatible with various communication protocols. This versatility ensures that they can be integrated seamlessly into any industrial environment, enhancing overall system performance and connectivity. With Phoenix Contact’s commitment to quality and innovation, their signal marshalling solutions stand as a testament to their capability in pushing the boundaries of automation technology.
-
Phoenix Contact
- Charging technology for e-mobility
- Terminal blocks
- Industrial communication
- Industrial lighting and signal lights
- Electronics housings
- Worker assistance systems
- Automation software
- Ferrules and crimp connectors
- Surge protection
- Safety relay modules and sensors
- DC/DC converters and DC/AC inverters
- PCB terminal blocks and PCB connectors
- Automatic tools
- Printers
- Uninterruptible power supplies (UPS)
- Hand tools
- Relays and optocouplers
- System cabling for controllers
- Power supplies
- Distributors, adapters, and conductor connectors
- Process indicators and field devices
- Redundancy modules
- Marking material
- Motor, machine, and system monitoring
- PLCs (controllers) and I/Os
- HMIs and IPCs
- I/O signal marshalling
- Cables and lines
- Energy monitoring
- Control cabinet accessories
- Connectors
- Device circuit breakers
- Motor starters and electronic switching devices
- Signal conditioners and measuring transducers
- Plug-in test system
- Edge computing
- Junction boxes and empty enclosures
- Distribution blocks
- Miscellaneous
- Board-to-board connectors
- Power distributors
- Ferrules
- Distribution blocks and device terminal blocks
- EMC filter
- Navigation
Filter products
22 Products Ready to Source
Fuse module for VIP I/O marshalling base elements with replaceable 2 A fuse in the field device supply path. Integrated test points and a disconnect knife allow uninterrupted signal measurement. HART transparent. Input/output module
Cable monitoring module for VIP I/O marshalling base elements. Enables cable fault monitoring when using standard switching contacts in safety applications. Both wire breaks and short circuits can be detected. Monitoring block
Fuse set, number: 10 Pcs., nominal current: 1 A, tripping characteristic: slow-blow (T) Fuse set
Fuse set, number: 10 Pcs., nominal current: 3.15 A, tripping characteristic: slow-blow (T) Fuse set
16-channel VIP I/O marshalling base element with 37-pos. D-SUB connector for universal use. Plug-in field and supply terminals available as accessories. With Push-in connection technology. For either Ex i or non-Ex. Base module
Plug for cold junction compensation for thermocouples, in combination with MACX MCR(-EX)-TC... temperature transducers Plug
Digital-to-analog converter for VIP I/O-Marshalling base elements. For connection of four digital inputs and conversion to a single analog 4...20 mA signal. Saves three I/O channels. Converter
Non-incendive, Ex ic impeding devices for VIP I/O marshalling base elements. For limiting current (60 mA or 80 mA) and voltage (26.4 V DC) on digital outputs. For example, to control solenoid valves in the Ex area (zone 2, CID2). Feed-through plug
Fuse module for VIP I/O marshalling base elements with replaceable 0.25 A fuse in the field device supply path. Integrated test points and a disconnect knife allow uninterrupted signal measurement. HART transparent. Input/output module
Fuse set, number: 10 Pcs., nominal current: 0.315 A, tripping characteristic: slow-blow (T) Fuse set
Fuse set, number: 10 Pcs., nominal current: 2.5 A, tripping characteristic: slow-blow (T) Fuse set
Connector set for standard applications for use with BASE-MSTB/D37M/16CH/EX VIP I/O marshalling base element with Push-in connection. Connector set
8-channel VIP I/O marshalling base element for universal use. All connections as screw connection technology. This module with the D-SUB 25 connector is pin compatible with the Foxboro I/A series DCS. Base module
Feed-through terminal block for VIP I/O marshalling base elements for conveying field signals to or from the I/O system. HART transparent. Feed-through plug
Fuse module for VIP I/O marshalling base elements with replaceable 0.5 A fuses in the field device supply path and in the signal path. Integrated test points and a disconnect knife allow uninterrupted signal measurement. HART transparent. Input/output module
Fuse module for VIP I/O marshalling base elements with replaceable 1 A fuses in the field device supply path and in the signal path. Integrated test points and a disconnect knife allow uninterrupted signal measurement. HART transparent. Input/output module
VIP I/O marshalling partition plate for safe isolation between non-Ex i and Ex i plug-in modules on a base module in VIP design. The partition plate is mounted directly on the base module between the plug-in IOAs. Partition plate
VIP I/O marshalling partition plate for safe isolation between non-Ex i and Ex i assembled base modules for Honeywell systems. The partition plate is mounted directly on the DIN rail at the end of the base module. Partition plate
VIP I/O marshalling partition plate for safe isolation between Ex i plug-in modules and the power supply of the VIP/MSTB/D50M/BASE/16CH/CX/EX base module. The partition plate is mounted directly on the base module between the plug-in IOAs and the power supply. Partition plate
Relay module for VIP I/O-Marshalling base elements. For switching 24 V DC loads up to max. 3 A. Integrated fuse and fuse failure indication. N/O contact or N/C contact can be used. Relay module
Relay module for VIP I/O-Marshalling base elements. For the electrically isolated coupling of 24 V DC field devices to digital inputs. Integrated fuse and fuse failure indication. Relay module
Plug kit for use with VIP/MSTB/D50M/BASE..., push-in connections Connector set